Date: 5th July 2016
270ZLD
Form 1 prime motor is the marine motor set technical specification of diesel engine ZC8270Set?modelCCFJ(2100-2184)X-WCCFJ(1900-2008)X-WCCFJ(1750-1874)X-W???????????Electric?generator?Rating?power???kW2100-21841900-20081750-1874Rating?voltage??????V400400400Rating?current???A?????????3788-39403428-36223157-3381Rating?frequency????????Hz505050Rating?power?factor?COS?0.8?Hysteresis?0.8?Hysteresis?0.8?Hysteresis?Rating?speed??????????r/min600600750Excitation?modeBrushlessBrushlessBrushlessInsulation?gradeB/FB/FB/FProtection?gradeIP23IP23IP23Phase?number?and?connectionthree-phase?four-wire/?three-phase?three-wirethree-phase?four-wire/?three-phase?three-wirethree-phase?four-wire/?three-phase?three-wire??????????????????Diesel?engineContinuous?rating?of?the?diesel?engine????kW???2400???2207???2060Maximum?power?of?the?diesel?engine????kW264024282266????????Rating?Speed?r/min750750750Minimum?idling?stabilized?speed?r/min300300240Number?of?cylinders888????????Cylinder?boremm?270270270?????????Piston?Stroke?mm385385385Lubricating?modeForce-feed?lubricationForce-feed?lubricationForce-feed?lubricationStarting?modeStarting?with?compressed?air?motorStarting?with?compressed?air?motor??Starting?with?compressed?air?motorFuel?consumption?Rate?g/kW.h182+5%182+5%182+5%Specific?oil?consumption?Rate?g/kW.h0.80.80.8???????Generator?setSteady?state?voltage?regulation??%?2.5?2.5?2.5Transient?voltage?regulation??%-15?+20-15?+20-15?+20???????Voltage?setting?time?S?1.5?1.5?1.5?????????Fluctuation?rate?of?Voltage??%?1?1?1Steady?state?rate?adjustment?frequency??%?5?It?can?be?adjusted?between?0-5??5?It?can?be?adjusted?between?0-5??5?It?can?be?adjusted?between?0-5?Transient?frequency?regulation??%?10?10?10??????Frequency?setting?time?S?5?5?5?????Frequency?fluctuation?rate??%?1?1?1The?setting?range?of?floating?voltagebetween?95%?and?105%?with?nominal?voltagebetween?95%?and?105%?with?nominal?voltagebetween?95%?and?105%?with?nominal?voltageThe technical characteristics of the set1.1 Operating environment?1.1.1 ?The set of operating environment may output nominal power in the following conditions, and continue to operate 12 hours in succession in the rated condition (including overload 10% to operate 1 hour) or continue to work within the time customers asking??Ambient pressure: 100Kpa??Ambient temperature:25???Relative humidity: 30%1.1.2 Under the following working conditions, the unit can work normally????Altitude: not more than:2000m??Ambient temperature: -5?; 40???Relative air humidity: no more than 90% (25?)1.2 ?The unit can be connected to or combined with the Internet1.3 ?The unit has the following safe-guard functions:a. overspeed protectionb. low oil pressure protection ? ? ? ? ? ? ? ? ? ??c. high oil temperature and high water temperature alarm ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??d. over voltage protectione. overload protectionf. over-current and short-circuit protection ? ? ? ? ? ? ? ? ? ?g. reverse power protectionh. low frequency protection (Limited to high pressure units)?i. under-voltage protection (Limited to high pressure units)j. differential protection (Limited to high pressure units)?
Images